Operation is equal to standard digital depth gauges, but it can not measure by installing extension rods. In case that measuring range is over 10mm, please use standard digital depth gauges.
Needle contact points |
Model | DMD-210S2 |
Resolution | 0.01 (mm) |
Range | 10 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-523 |
Measuring force | 2.0 or less(N) |
Weight | 270 (g) |
Ø2 Flat Needle contact points |
Model | DMD-211S2 |
Resolution | 0.01 (mm) |
Range | 10 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø2 Flat |
Standard contact point |
ZS-530 |
Measuring force | 2.0 or less(N) |
Weight | 270 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-213S2 |
Resolution | 0.01 (mm) |
Range | 10 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel Ball |
Standard contact point |
ZS-034 |
Measuring force | 2.0 or less(N) |
Weight | 270 (g) |
Needle contact points |
Model | DMD-250S2 |
Resolution | 0.01 (mm) |
Range | 5 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-518 |
Measuring force | 2.0 or less(N) |
Weight | 205 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-252S2 |
Resolution | 0.01 (mm) |
Range | Concave 5 (mm), Convex 4 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-595 |
Measuring force | 2.0 or less(N) |
Weight | 200 (g) |
Needle contact points |
Model | DMD-2100S2 |
Resolution | 0.001 (mm) |
Range | 10 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-523 |
Measuring force | 2.0 or less(N) |
Weight | 300 (g) |
Ø2 Flat Needle contact points |
Model | DMD-2110S2 |
Resolution | 0.001 (mm) |
Range | 10 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Ø2 Flat |
Standard contact point |
ZS-530 |
Measuring force | 2.0 or less(N) |
Weight | 300 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-2130S2 |
Resolution | 0.001 (mm) |
Range | 10 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 2.0 or less(N) |
Weight | 300 (g) |
Needle contact points |
Model | DMD-2500S2 |
Resolution | 0.001 (mm) |
Range | 5 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-518 |
Measuring force | 2.0 or less(N) |
Weight | 235 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-2520S2 |
Resolution | 0.001 (mm) |
Range | Concave 5 (mm), Convex 4 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-595 |
Measuring force | 2.0 or less(N) |
Weight | 230 (g) |
Needle contact points |
Model | DMD-210J |
Resolution | 0.01 (mm) |
Range | 12 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-523 |
Measuring force | 1.0 or less(N) |
Weight | 310 (g) |
Ø2 Flat needle contact points |
Model | DMD-211J |
Resolution | 0.01 (mm) |
Range | 12 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø2 Flat |
Standard contact point |
ZS-530 |
Measuring force | 1.0 or less(N) |
Weight | 310 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-213J |
Resolution | 0.01 (mm) |
Range | 12 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 1.0 or less(N) |
Weight | 310 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-214J |
Resolution | 0.01 (mm) |
Range | 12(220) (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 2.3 or less(N) |
Weight | 335 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-215J |
Resolution | 0.01 (mm) |
Range | 12(220) (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 2.3 or less(N) |
Weight | 375 (g) |
Needle contact points |
Model | DMD-240J |
Resolution | 0.01 (mm) |
Range | 25.4 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-113 |
Measuring force | 1.6 or less(N) |
Weight | 390 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-241J |
Resolution | 0.01 (mm) |
Range | 25.4 (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-600 |
Measuring force | 1.6 or less(N) |
Weight | 370 (g) |
Ø3.2 Steel ball contact points |
With 5-Extension rods |
Model | DMD-293J |
Resolution | 0.01 (mm) |
Range | 12(220) (mm) |
Accuracy | ±20 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 2.3 or less(N) |
Weight | 545 (g) |
Needle contact points |
Model | DMD-2100J |
Resolution | 0.001 (mm) |
Range | 12 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-523 |
Measuring force | 1.0 or less(N) |
Weight | 310 (g) |
Ø3.2 Steel ball contact points |
With 5-Extension rods |
Model | DMD-2150J |
Resolution | 0.001 (mm) |
Range | 12(220) (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-034 |
Measuring force | 2.3 or less(N) |
Weight | 375 (g) |
Needle contact points |
Model | DMD-2400J |
Resolution | 0.001 (mm) |
Range | 25.4 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Needle |
Standard contact point |
ZS-113 |
Measuring force | 1.6 or less(N) |
Weight | 390 (g) |
Ø3.2 Steel ball contact points |
Model | DMD-2410J |
Resolution | 0.001 (mm) |
Range | 25.4 (mm) |
Accuracy | ±5 (µm) |
Contact point form |
Ø3.2 Steel ball |
Standard contact point |
ZS-600 |
Measuring force | 1.6 or less(N) |
Weight | 370 (g) |